All cables from #10 AWG through #16 AWG have zip cords for easy removal of the outer jacket.
Required cable length equals track length plus 10% plus length required for end connections
Standard Copper Cable (Model FC)
The following numerical data was used to calculate braid angle and shield coverage (per QQB-575B1 PARA.4.3.2.)
Required cable length equals track length plus 10% plus length required for end connections
Standard Copper Cable (Model FC)
- Yellow PVC Jacketed Flat Cable - 600 Volt AC Rated
- Extra Flexible, Color Coded According to NEMA Standards
- UL and CSA -40°C to +105"C (-40°F to +221 °F) Temperature Range
- 600 Volt AC Rated
- Standard Cable with Tinned Copper Braided Shield
- 95.7% Min. RFI Rating
- Black Heat Shrink Tubing Outer Cover
The following numerical data was used to calculate braid angle and shield coverage (per QQB-575B1 PARA.4.3.2.)
Braid Angle A = 24
Coverage K = 99
Diamete'of Shield D = 0.750
Strand Diameter d =0.005
Picks per inch P = 9
Number of Carriers C = 96
Strands per Carrier N = 9
NPd/sina F = 99118776
Item # |
Type |
Number of Conductors |
AWG Wire Size |
Continuous Duty Rating at 30°C (86°F) Ambient |
Number of Strands per Conductor |
Weight |
Nominal Dimensions Unshielded Cable |
---|---|---|---|---|---|---|---|
FC-42 | N/A Yellow PVC Jacket | N/A 4 | N/A #2 | N/A 130 A | N/A 665 | N/A 1.342 lb/ft | N/A 0.575 x 1.975 in |
FC-44 | N/A Yellow PVC Jacket | N/A 4 | N/A #4 | N/A 95 A | N/A 420 | N/A 0.896 lb/ft | N/A 0.515 x 1.750 in |
FC-46 | N/A Yellow PVC Jacket | N/A 4 | N/A #6 | N/A 75 A | N/A 266 | N/A 0.620 lb/ft | N/A 0.435 x 1.490 in |
FC-48 | N/A Yellow PVC Jacket | N/A 4 | N/A #8 | N/A 50 A | N/A 168 | N/A 0.401 lb/ft | N/A 0.375 x 1.225 in |
FC-410 | N/A Yellow PVC Jacket | N/A 4 | N/A #10 | N/A 40 A | N/A 105 | N/A 0.239 lb/ft | N/A 0.290 x 0.890 in |
FC-412 | N/A Yellow PVC Jacket | N/A 4 | N/A #12 | N/A 30 A | N/A 65 | N/A 0.180 lb/ft | N/A 0.260 x 0.800 in |
FC-414 | N/A Yellow PVC Jacket | N/A 4 | N/A #14 | N/A 25 A | N/A 41 | N/A 0.138 lb/ft | N/A 0.240 x 0.690 in |
FC-712 | N/A Yellow PVC Jacket | N/A 7 | N/A #12 | N/A 21 A | N/A 65 | N/A 0.308 lb/ft | N/A 0.260 x 1.310 in |
FC-812 | N/A Yellow PVC Jacket | N/A 8 | N/A #12 | N/A 20 A | N/A 65 | N/A 0.343 lb/ft | N/A 0.260 x 1.440 in |
FC-814 | N/A Yellow PVC Jacket | N/A 8 | N/A #14 | N/A 17 A | N/A 41 | N/A 0.254 lb/ft | N/A 0.240 x 1.290 in |
FC-816 | N/A Yellow PVC Jacket | N/A 8 | N/A #16 | N/A 15 A | N/A 65 | N/A 0.194 lb/ft | N/A 0.225 x 1.170 in |
FC-1214 | N/A Yellow PVC Jacket | N/A 12 | N/A #14 | N/A 17 A | N/A 41 | N/A 0.380 lb/ft | N/A 0.240 x 1.825 in |
FC-1216 | N/A Yellow PVC Jacket | N/A 12 | N/A #16 | N/A 15 A | N/A 65 | N/A 0.292 lb/ft | N/A 0.225 x 1.700 in |
SFC-46 | N/A Shielded Flat Cable | N/A 4 | N/A #6 | N/A 75 A | N/A 266 | N/A 0.620 lb/ft | N/A 0.435 x 1.490 in |
SFC-48 | N/A Shielded Flat Cable | N/A 4 | N/A #8 | N/A 50 A | N/A 168 | N/A 0.401 lb/ft | N/A 0.375 x 1.225 in |
SFC-410 | N/A Shielded Flat Cable | N/A 4 | N/A #10 | N/A 40 A | N/A 105 | N/A 0.239 lb/ft | N/A 0.290 x 0.890 in |
SFC-412 | N/A Shielded Flat Cable | N/A 4 | N/A #12 | N/A 30 A | N/A 65 | N/A 0.180 lb/ft | N/A 0.260 x 0.800 in |
SFC-414 | N/A Shielded Flat Cable | N/A 4 | N/A #14 | N/A 25 A | N/A 41 | N/A 0.138 lb/ft | N/A 0.240 x 0.690 in |
SFC-712 | N/A Shielded Flat Cable | N/A 7 | N/A #12 | N/A 21 A | N/A 65 | N/A 0.308 lb/ft | N/A 0.260 x 1.310 in |
SFC-812 | N/A Shielded Flat Cable | N/A 8 | N/A #12 | N/A 20 A | N/A 65 | N/A 0.343 lb/ft | N/A 0.260 x 1.440 in |
SFC-814 | N/A Shielded Flat Cable | N/A 8 | N/A #14 | N/A 17 A | N/A 41 | N/A 0.254 lb/ft | N/A 0.240 x 1.290 in |
SFC-816 | N/A Shielded Flat Cable | N/A 8 | N/A #16 | N/A 15 A | N/A 65 | N/A 0.194 lb/ft | N/A 0.225 x 1.170 in |
SFC-1214 | N/A Shielded Flat Cable | N/A 12 | N/A #14 | N/A 17 A | N/A 41 | N/A 0.380 lb/ft | N/A 0.240 x 1.825 in |
SFC-1216 | N/A Shielded Flat Cable | N/A 12 | N/A #16 | N/A 15 A | N/A 65 | N/A 0.292 lb/ft | N/A 0.225 x 1.700 in |